| Technical Info & Specs | |
| Technical Data: | |
|---|---|
| Maximum Operating Pressure | 10 bar (145 PSI / 1000kPa) |
| Temperature Range | -20° ti + 80°C (-40°F to +176°F) |
| Air Condition | Filtered to 40 microns lubricated or dry |
| Flow Rate at 6 Bar (87 PSI / 600kPa) | 19dm3 / sec (40 SCFM) |
| Ports | ISO R228 (1/8' BSP) standard or NPT |
| Weights | Cover/Unguarded 800grms / Guarded 1.5kg |
| Connection Information | |
|---|---|
|
Valve connected as a 3/2 Normally Closed valve
* The air supply should be connected to Port 1. * Port 2 is redundant and should be plugged with the plug fitting supplied. * The outlet is connected to Port 4. * Ports 3 and 5 are exhaust ports and should be left open to atmosphere or fitted with silencers. See note below. |
|
|
Valve connected as a 3/2 Normally Open valve
* The air supply should be connected to Port 1. * Port 4 is redundant and should be plugged with the plug fitting supplied. * The outlet is connected to Port 2. * Ports 3 and 5 are exhaust ports and should be left open to atmosphere or fitted with silencers. See note below. |
|
|
Valve connected as 5/2 valve
* The air supply should be connected to Port 1. * Ports 2 and 4 are outlet or cylinder ports. * Ports 3 and 5 are exhaust ports and should be left open to atmosphere or fitted with silencers. See note below. |
|